400Hz Ground Power Unit
Product introduction
The aircraft ground static variable power supply is a 400Hz AC power supply equipment specially developed for the airport, airline, aviation industry department and army for the ground power supply needs of aircraft and airborne equipment by our company with the latest power electronics and intelligent control technology. The products can be widely used in boarding bridge, apron, hangar, accessory workshop, laboratory and other places, with the advantages of good waveform quality, small volume, light weight, low noise, no pollution, low operating cost, etc.
Product Description
Technical features
– The leading parallel and redundancy technology of multi machine power supply without master-slave directly breaks through the bottleneck of capacity expansion and improves operation reliability.
– The instantaneous waveform tracking control technology makes the output voltage harmonic, phase voltage modulation and dynamic characteristics reach the international advanced level.
– Unique current real-time control and interception technology, fully suitable for motor and rectifier impact load.
The three-phase voltage decoupling control technology can adapt to any unbalanced load.
– 12 pulse rectifier transformer and rectifier components can reduce the harmonic current injected into the power grid and reduce the impact on the power grid. APF module can be selected, and the harmonic of the input current is as low as 5%.
– It has the advantages of advanced technology, high safety, modular design, light weight and good maintainability.
– The latest generation IGBT module realizes high-power converter, with standard power level of 180KVA and maximum field operation capacity of 450kva, which is the most in the industry.
– DSP intelligent monitoring, VFD fluorescent Chinese display and external control / communication interface, convenient operation.
– It can provide up to 30 kinds of self diagnosis information, and the fault can be directly located to the original part, which is convenient for maintenance.
Compliance with standards
– GJB 181 aircraft power supply characteristics
– GJB 572 aircraft ground power supply characteristics and general requirements
– MH / T 6018 aircraft ground static power supply
– Power supply characteristics of mil-std-704f aircraft
– ISO 6858 General requirements for aircraft ground support power supply
– Characteristics of DFS 400 aviation power supply
– En55011 radiation of industrial, scientific and medical equipment
– En61000-4-3 electromagnetic compatibility radio frequency anti-interference function
– En61000-4-4 electromagnetic compatibility fast pulse anti-interference test
– En61000-4-2 electromagnetic compatibility electrostatic anti-interference test
Typical configuration
– Bridge mounted power supply
– Pylons
– Input cable
– Cable retracting device (lifting type or reel type)
– Remote control operation device
Technical specifications
| Model | ACME400-3360 | ACME400-33900 | ACME400-331200 | ACME400-331500 | ACME400-331800 | |
| Capacity | 60KVA | 90KVA | 120KVA | 150KVA | 180KVA | |
| Input | Voltage | 380(1±15%)V(Continuous fluctuation)/380(1±20%)V(Transient fluctuation, derating use) | ||||
| Frequency | 50(1±10%)Hz | |||||
| PF | ≥0.96 | |||||
| Impulse current | Soft start, no impact | |||||
| Output | Rating voltage | Three phase four wire 115/200V | ||||
| Rating frequency | 400Hz | |||||
| Voltage stability | ± 1% FS (note FS means full scale) | |||||
| Voltage adjust range | ≥115*(1±15%)V | |||||
| Frequency stability | ±0.01% | |||||
| Dynamic characteristics | Voltage overshoot < 8%, recovery time < 10ms, frequency overshoot < 0.1%, recovery time < 10ms | |||||
| Harmonic content | Total harmonic content < 1.5%, single harmonic content < 1% (linear load) | |||||
| Peak coefficient of voltage | 1.414±0.05 | |||||
| Voltage modulation | < 1%, the modulation spectrum meets the requirements of MH / t6018 and iso6858 | |||||
| Three phase unbalance | Phase voltage difference < 2V | |||||
| Phase | 120±1˚(no load or balanced load) / 120±1.5˚(1 / 3 unbalanced load) | |||||
| Voltage regulation | 115V ± 1V (symmetrical load changes within 0-100%), 115V ± 1.5V (30% asymmetrical load) | |||||
| Adaptive load PF | 0.6 (lagging) – 0.95 (leading) | |||||
| Voltage compensation | Maximum compensation 10V | |||||
| Comprehensive characteristics | Overload ability | 110%, continuous operation; 125%, 600s; 150%, 60s; 200%, 10s; | ||||
| Protection function | Input over-voltage, under voltage, phase loss; output open circuit, EF interlock protection, poor plug-in protection, internal fault Output short circuit, overload, overvoltage, Underfrequency, phase failure or phase sequence error, inverter overcurrent, internal overheating | |||||
| Operation display | VFD | |||||
| Electromagnetic compatibility | Meet the requirements of iec61000-6-2, iec61000-6-4, etc | |||||
| Efficiency | Rated condition | ≥94% | ||||
| Standby power | <50W | |||||
| No load power consumption | <2kw | |||||
| Reliability and life | MTBF | ≥1*105h | ||||
| MTTR | ≤20min | |||||
| Service life | ≥20 years | |||||
| Environment | Working temperature | -40℃-70℃ | ||||
| Humidity | ≤95%(25℃) | |||||
| Storage temperature | -50℃-55℃ | |||||
| Noise | <60dB(A),within 1m, height 1.5m measurement | |||||
| Protection level | IP20/IP55 | |||||
| Size(Wmm*Dmm*Hmm) | 1000*900*600(Horizontal) 610*1000*1510(Vertical) | 1600*1100*700(Horizontal) 660*1000*1785(Vertical) | ||||
| Trailer W*H*D(mm) | 1985*1385*1090(trailer inclusive) | 1400*1400*2760(Trailer inclusive) | ||||
| Weight(Kg) | 450 | 480 | 850 | 1050 | 1150 | |